Application Tips

 Sequencing Timer Examples

    Choose An Example:  
 
Example A:  Sequencing Mode Using 2 Pumps:

Set the timer so that Relay A is on for 15 minutes and off for 5 minutes. Then turn Relay B on for 10 minutes and off for 3 minutes. Only one relay can be on at a time.

By filling only one grow bed at a time and allowing it to drain, this insures that there is sufficient water in the sump tank.
  1. Go to Settings » Relay A » Mode and select Index Timer. Press the Next/Enter button to save the setting.

         Change Mode

  2. Go to Settings » Relay A »Time On and set the time to 015:00. Choose Save and press the Next/Enter button.

         On Time

  3. Go to Settings » Relay A » Time Off and set the time to 005:00. Choose Save and press the Next/Enter button.

         Off Time

  4. Go to Settings » Relay B » Time On and set the time to 010:00. Choose Save and press the Next/Enter button.

         On Time

  5. Go to Settings » Relay B » Time Off and set the time to 003:00. Choose Save and press the Next/Enter button.

         Off Time

  6. Return back to the home screen. It will display the current relay status, and the amount of time until the next event occurs.

         Main Menu


2 Pumps with 1 Sump
 


2 Pumps with 1 Sump Chart


Note:   Typically flood and drain times for this type of setup are much longer.  These values are used to just display the various times that this timer is capable of using.
Copyright 2010-15, Bigelow Brook Farm, LLC